- 当前位置:首页 > >Merck Millipore > 生命科学研究
- 生命科学研究
-

-
merck millipore,默克密理博,FCCS025106,FlowCellect™ MAPK Activation Dual Detection Kit
产品名称:FlowCellect™ MAPK Activation Dual Detection Kit
产品型号:FCCS025106
This FlowCellect MAPK Activation Dual Detection Kit for Flow Cytometry includes 2 conjugated antibodies, phospho-specific Anti-phospho-ERK1/2 (Thr202/Tyr204, Thr185/Tyr187)-PE & Anti-ERK1/2-Alexa Fluo More>>
merck millipore,默克密理博,FCCS025106,FlowCellect™ MAPK Activation Dual Detection Kit
- 产品介绍
描述 产品目录编号 FCCS025106 商名 - FlowCellect
描述 FlowCellect™ MAPK Activation Dual Detection Kit 概述 Millipore’s FlowCellect™ MAPK Activation Dual Detection kit includes two directly conjugated antibodies, a phospho-specific Anti-phospho-ERK1/2 (Thr202/Tyr204, Thr185/Tyr187)-PE and an Anti-ERK1/2-Alexa Fluor® 647 conjugated antibody to measure total levels of ERK. This two color flow cytometry kit is designed to measure the extent of MAPK phosphorylation relative to the total MAPK expression in any given cell population. By doing such, the levels of both the total and phosphorylated protein can be measured simultaneously in the same cell, resulting in a normalized and accurate measurement of MAPK activation after stimulation. Moreover, simultaneous measurement of both total and phospho-ERK1/2 confirms target specificity of the phosphorylation event. Together, a total and phospho antibody duo performed in multiplex provides an enhanced and more reliable detection of the phospho:total ratio within a mixed population.
All FlowCellect kits are supplied with optimized fixation, permeabilization, wash, and assay buffers to provide researchers the ability to detect the activation of ERK in flow applications. Sufficient reagents are provided for 25 two-color samples. The kit includes all optimized fluorescently labeled antibodies and buffers necessary for cell preparation and analysis.Alternate Names - Flow Cellect
背景信息 Erk (Extracellular signal-Related Kinase) is a family of two, highly homologous proteins denoted as Erk1 (p44, MAPK3) and Erk2 (p42, MAPK1) that both function in the same pathway. The two proteins are often referred to collectively as Erk1/2 or p44/p42 MAP kinase. The Erk pathway is considered the classical, canonical MAPK (Mitogen-Activated Protein Kinase) signaling pathway. It is an evolutionarily conserved pathway that controls and is a critical regulator of the growth and survival through the promotion of cell proliferation and the prevention of apoptosis. Erk is involved in the control of many fundamental cellular processes including cell proliferation, survival, differentiation, apoptosis, motility and metabolism. Erk is activated by growth factor stimulation of receptor tyrosine kinases (RTKs), GPCR, and/or integrin stimulation. This activates the Ras-Raf-MEK-Erk pathway that results in the phosphorylation/activation of Erk1/2 (p44/p42) on the TxY motif (Thr202/Tyr204 and Thr185/Tyr187 for Erk1 & Erk2, respectively).
The regulation of a large number of cellular processes (such as cell proliferation/differentiation, cell survival and apoptosis) is dependent on the activation of MAPK signaling pathway, which can be measured by the phosphorylation of ERK1/2.产品信息 部件 - 6. 1X Permeabilization Buffer: (Part No. CS203284) One bottle containing 13 mL.
- 1. 20X Anti-phospho-ERK1/2 (Thr202/Tyr204, Thr185/Tyr187) PE Conjugated Antibody: (Part No. CS203329) One vial containing 150 µL.
- 2. 20X Anti-ERK1/2-Alexa Fluor® 647 Conjugated Antibody: (Part No. CS205075) One vial containing 150 µL.
- 3. Fixation Buffer: (Part No. CS202122) One bottle containing 13 mL.
- 4. 10X Wash Buffer: (Part No. CS202123) One bottle containing 13 mL.
- 5. 5X Assay Buffer: (Part No. CS202124) One 55 mL bottle
检测方法 Fluorescent 应用 应用 This FlowCellect MAPK Activation Dual Detection Kit for Flow Cytometry includes 2 conjugated antibodies, phospho-specific Anti-phospho-ERK1/2 (Thr202/Tyr204, Thr185/Tyr187)-PE & Anti-ERK1/2-Alexa Fluor 647 to measure total levels of ERK. 主要应用 - Flow Cytometry
生物信息 宿主 Mouse 品种反应性 Human 抗体类型 Monoclonal Antibody 产品使用声明 质量保证 Lot to lot in-process testing on all kit components 使用声明 - Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
- Alexa Fluor® is a registered trademark of Molecular Probes, Inc.
储存和货运信息 存储条件 4-8°C for antibodies and buffers 包装信息 数量 25 Tests / Kit
上一件merck millipore产品:merck millipore,默克密理博,04-795,Anti-phospho-Ribosomal Protein S6 (Ser235) Antibody, clone MC27, rabbit monoclonal
下一件merck millipore产品:merck millipore,默克密理博,04-1507,Anti-CD265/RANK Antibody, clone R12-31
merck millipore,默克密理博,MAB1532,Anti-Hexokinase Type I Antibody, a.a. 191-209, clone 21
merck millipore,默克密理博,492002,NOX1 Inhibitor, ML171 - CAS 6631-94-3 - Calbiochem
merck millipore,默克密理博,ABT304,Anti-TAGLN Antibody
merck millipore,默克密理博,ABE43,Anti-Ebp1 NT Antibody
merck millipore,默克密理博,04-795,Anti-phospho-Ribosomal Protein S6 (Ser235) Antibody, clone MC27, rabbit mo...
merck millipore,默克密理博,04-1507,Anti-CD265/RANK Antibody, clone R12-31
merck millipore,默克密理博,658552,AG 1478 - CAS 175178-82-2 - Calbiochem
merck millipore,默克密理博,ABC245,Anti-REDD1 Antibody
merck millipore,默克密理博,05-1526,Anti-Importin subunit alpha-1 Antibody, clone 8G5
merck millipore,默克密理博,FCCH100105,FlowCellect MitoPotential Red Kit


