• merck millipore,默克密理博,ECM557,QCM™ Leukocyte Transendothelial Migration Assay  (Colorimetric, 24 Assays)
  • merck millipore,默克密理博,ECM557,QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)

    产品名称:QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)
    产品型号:ECM557
    This Colorimetric QCM Leukocyte Transendothelial Cell Migration Assay provides an efficient model to analyze the ability of leukocytes to migrate through the endothelium.

    merck millipore,默克密理博,ECM557,QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)

  • 产品介绍
  • merck millipore,默克密理博,ECM557,QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)

    重要规格表

    检测方法
    Colorimetric
    描述
    产品目录编号 ECM557
    商名
    • Chemicon
    • QCM
    描述 QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)
    概述 Also available: Cell Comb™ Scratch Assay! Get biochemical data from a scratch assay!

    Introduction
    Millipore’s Colorimetric QCM™ Leukocyte Transendothelial Cell Migration Assay provides an efficient model to analyze the ability of leukocytes to migrate through the endothelium. The assay is designed with a 3 µm pore size cell culture insert, appropriate for most leukocyte migration. The upper side of the cell culture insert is coated with fibronectin to support the optimal attachment and growth of endothelial cells. The assay allows investigators to evaluate the effects of various factors that influence the transendothelial process.

    Precoated cell culture inserts are provided in the Millipore QCM Leukocyte Transendothelial Cell Migration Assay to significantly reduce assay time. Additionally, the assay allows quantitative analysis of leukocyte migration. Following incubation of leukocytes with the endothelial cell layer, migratory cells are stained and quantified with WST-1 reagent and measured using a spectrophotometer. Absorbance correlates with cell migration.
    背景信息 Leukocytes patrol the vascular system. They must migrate across endothelial barriers in order to recruit to sites of inflammation. This process involves a multistep cascade consisting of leukocyte rolling, adhesion, and transmigration. A quantitative assay for leukocyte transendothelial migration has been described using a modified Boyden chamber system (Roth et al. 1995, Ding et al. 2000). The Boyden chamber system is a two chamber system with a porous membrane providing an interface between these two chambers. Endothelial cells are cultured on top of the porous membrane that is coated with an extracelluar matrix (ECM) protein. Once a confluent layer of cells is established, leukocytes are then added onto the endothelial monolayer. Leukocyte migration across the endothelium is determined by measuring the number of cells that migrate between the endothelial cells, through the porous membrane, to the lower chamber.

    产品信息
    部件
    • 7. Forceps: (Part No. 10203) 1 pair
    • 1. Migration Test Plate: (Part No. CS202626) Two 24-well culture plates, each containing 12 human fibronectin-coated cell culture inserts (3 μm pore size), sufficient for the evaluation of 24 test samples
    • 2. TNFα: (Part No. 2004167) One tube - 20 μL at 0.1 mg/mL
    • 3. Cell Stain Solution: (Part No. 20294) One vial - 10 mL
    • 4. WST-1 Reagent: (Part No. CS201370) One vial.
    • 5. Electro Coupling Solution: (Part No. CS201382) One vial - 5 mL.
    • 6. 96 well Stain Quantitation Plate: (Part No. 2005870) One plate.
    检测方法 Colorimetric
    应用
    应用 This Colorimetric QCM Leukocyte Transendothelial Cell Migration Assay provides an efficient model to analyze the ability of leukocytes to migrate through the endothelium.
    应用说明 Results of the assay may be illustrated graphically using a bar chart to display optical density (OD) values at 420 - 480 nm.

    Additional migration may also be induced or inhibited in test wells through the addition of cytokines or other pharmacological agents.
    Figures 2 and 3 demonstrate typical migration results. One should use the data for reference only. This data should not be used to interpret actual assay results.

    产品使用声明
    使用声明
    • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
    储存和货运信息
    存储条件 The kit is packaged in two individual boxes. ECM557-1 contains components that upon arrival should be stored at 2° to 8°C. ECM557-2 contains TNFα , WST-1, and Electro Coupling Solution that upon arrival should be stored at -20°C. Please refer to kit label for expiration date.
    包装信息
    数量 1 kit
    包装 24 Assays

    merck millipore,默克密理博,ECM557,QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)

上一件merck millipore产品:merck millipore,默克密理博,MAB505S,Mouse Anti-Rat IgG2b γ2b chain Antibody, Cy5 conjugate
下一件merck millipore产品:merck millipore,默克密理博,ABN518,Anti-CPT1 AntibodyA



whatman,沃特曼,nalgene,耐洁,merck millipore,默克密理愽,sartorius,赛多利斯,pall,颇尔
thermo fisher,赛默飞世尔,GE,MN,macherey-nagel,advantec,wheaton,brand,普兰德,welch,airtech


上海羽令过滤器材有限公司版权所有 Copyright ©  www.yl-guolv.com  Powered by 羽令集团—信息技术部