• merck millipore,默克密理博,SCR580,STEMCCA Viral Gene Detection qPCR Kit (Human)
  • merck millipore,默克密理博,SCR580,STEMCCA Viral Gene Detection qPCR Kit (Human)

    产品名称:STEMCCA Viral Gene Detection qPCR Kit (Human)
    产品型号:SCR580
    The STEMCCA Viral Gene Detection qPCR Multiplex Kit (Human) will help determine whether an iPS clone generated with the STEMCCA lentivirus is a fully reprogrammed colony or a partially reprogrammed in More>>

    merck millipore,默克密理博,SCR580,STEMCCA Viral Gene Detection qPCR Kit (Human)

  • 产品介绍
  • merck millipore,默克密理博,SCR580,STEMCCA Viral Gene Detection qPCR Kit (Human)

    描述
    产品目录编号 SCR580
    商名
    • STEMCCA
    描述 STEMCCA Viral Gene Detection qPCR Kit (Human)
    背景信息 Induced pluripotent stem (iPS) cells can be generated from somatic cells by enforced expression of four Yamanaka transcription factors, Oct4, Klf4, Sox2, and c-Myc (Takahashi and Yamanaka, 2006). True pluripotency is defined as the ability to give rise to all cell types except for extra-embryonic tissues. Recent findings suggest that factor-induced reprogramming primarily generates an undifferentiated intermediate cell state that is not completely pluripotent (Jaenisch and Young, 2008). These partially reprogrammed cells (pre-iPS or Class I iPS cells) have global gene expression and DNA methylation patterns that are distinct from ES cells in spite of similaries in colony morphology and the ability to be propagated extensively in culture. Partial reprogrammed cells are characterized by the continued expression of viral transgenes, the incomplete expression of pluripotent genes such as Nanog and Rex1, down-regulation of somatic cell marker genes, and the inability to generate adult chimeric mice and transmit through the germ line (Silva J, 2008).

    The STEMCCA Viral Gene Detection qPCR Multiplex Kit (Human) will help determine whether an iPS clone generated with the STEMCCA lentivirus is a fully reprogrammed colony or a partially reprogrammed intermediate. This real time PCR kit has been designed to detect STEMCCA viral transgene expression along with the upregulation of human Nanog, a key ES/iPS cell pluripotency marker, in a multiplex setting enabled by the proprietary Amplifluor® technology.
    产品信息
    部件
    • 8. PCR grade water (Part number 90411): One (1) vial containing 8 mL of nuclease-free water.
    • 1. Amplifluor Conjugated Viral OCT-4 FAM Forward Primer, 25X (Part number CS204499): One (1) vial containing 100 µL (100 reactions).
    • 2. Amplifluor Conjugated Human Nanog JOE Forward Primer, 25X (Part number CS204425): One (1) vial containing 100 µL (100 reactions).
    • 3. Amplifluor Conjugated Human/Mouse GAPDH Texas Red® Forward Primer, 25X (Part number CS204431): One (1) vial containing 100 µL (100 reactions).
    • 4. Viral OCT-4 Reverse Primer, 25X (Part number CS204493): One (1) vial containing 100 µL (100 reactions).
    • 5. Human Nanog Reverse Primer (Part number CS204459): One (1) vial containing 100 µL (100 reactions.
    • 6. Human/Mouse GAPDH Reverse Primer (Part number CS204489): One (1) vial containing 100 µL (100 reactions.
    • 7. Positive Control-HN (Part number CS204492): One (1) vial containing 100 µL (10e9 copies/5 µL).
    应用
    应用 The STEMCCA Viral Gene Detection qPCR Multiplex Kit (Human) will help determine whether an iPS clone generated with the STEMCCA lentivirus is a fully reprogrammed colony or a partially reprogrammed intermediate.
    主要应用
    • PCR
    应用说明 Texas Red® is a registered trademark of Life Technologies.
    产品使用声明
    使用声明
    • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
    储存和货运信息
    存储条件 Amplifluor primers are light sensitive and must be stored in the dark at -20°C or at -80°C for long term storage. Amplifluor primers may be divided into convenient aliquots and placed in amber or foil-wrapped tubes to minimize light exposure. Reverse primers and positive control should be stored at or below -20°C.
    包装信息
    数量 100 Reactions/Kit

    merck millipore,默克密理博,SCR580,STEMCCA Viral Gene Detection qPCR Kit (Human)

上一件merck millipore产品:merck millipore,默克密理博,09-294,Anti-phospho Calmodulin (Tyr138) Antibody
下一件merck millipore产品:merck millipore,默克密理博,AB8143,Anti-Connexin 26 Antibody



whatman,沃特曼,nalgene,耐洁,merck millipore,默克密理愽,sartorius,赛多利斯,pall,颇尔
thermo fisher,赛默飞世尔,GE,MN,macherey-nagel,advantec,wheaton,brand,普兰德,welch,airtech


上海羽令过滤器材有限公司版权所有 Copyright ©  www.yl-guolv.com  Powered by 羽令集团—信息技术部