- 当前位置:首页 > >Merck Millipore > 生命科学研究
- 生命科学研究
-

-
merck millipore,默克密理博,SCR511,STEMCCA Cre-Excisable Constitutive Polycistronic (OKSM) Lentivirus Reprogramming Kit
产品名称:STEMCCA Cre-Excisable Constitutive Polycistronic (OKSM) Lentivirus Reprogramming Kit
产品型号:SCR511
The STEMCCA Cre-Excisable Constitutive Polycistronic Lentivirus Kit contains high titer polycistronic lentivirus & Polybrene transfection reagent that have been validated for the generation of mouse & More>>
merck millipore,默克密理博,SCR511,STEMCCA Cre-Excisable Constitutive Polycistronic (OKSM) Lentivirus Reprogramming Kit
- 产品介绍
- merck millipore,默克密理博,SCR511,STEMCCA Cre-Excisable Constitutive Polycistronic (OKSM) Lentivirus Reprogramming Kit
描述 产品目录编号 SCR511 商名 - STEMCCA
描述 STEMCCA Cre-Excisable Constitutive Polycistronic (OKSM) Lentivirus Reprogramming Kit 概述 The STEMCCA Cre-Excisable Constitutive Polycistronic (OKSM) Lentivirus Kit contains high titer polycistronic (OKSM) lentivirus and Polybrene transfection reagent that have been validated for the generation of mouse and human induced pluripotent stem cells from mouse embryonic fibroblasts (MEFs) and human foreskin fibroblasts (HFFs), respectively. The Cre-excisable STEMCCA vector, comprised of the transcription factors Oct-4, Klf4, SOX-2, and c-Myc (OKSM) separated by the self-cleaving 2A peptide and IRES sequences, includes flanking LoxP sites that enable Cre-mediated excision of the vector following reprogramming (Sommer CA, 2009). The use of a single polycistronic lentiviral vector significantly improves reprogramming efficiencies and reduces the number of viral integrations. Furthermore, the ability to remove the reprogramming vector has been shown to improve the developmental potential of iPS cells and significantly increase their capacity to undergo directed differentiation in vitro (Sommer CA, 2010).
Important note: the STEMCCA lentivirus reprogramming kits are provided in two formats, dependent on whether you are working with a human or mouse system. Human reprogramming experiments require a higher multiplicity of infection (MOI) than mouse experiments. Therefore, the larger, three-vial kits are required for human reprogramming experiments. If you are reprogramming mouse embryo fibroblast cells, you have the option to use either the one- or three-vial kit, depending on how many wells you want to infect. Reprogramming other rodent somatic cells may require more than one vial of lentivirus to perform at optimal MOI.产品信息 部件 - 2. Polybrene Transfection Reagent: (Part number TR-1003-50UL) One (1) vial containing 50 µL of 10 mg/mL stock.
- 1. EF1α-STEMCCA-LoxP (OKSM) Lentivirus: (Part number CS204439) One (1) vial containing 15 µL of high titer lentivirus.
应用 应用 The STEMCCA Cre-Excisable Constitutive Polycistronic Lentivirus Kit contains high titer polycistronic lentivirus & Polybrene transfection reagent that have been validated for the generation of mouse & human induced pluripotent stem cells. 产品使用声明 质量保证 Tested to confirm the generation of iPS cells from p3 mouse embryonic fibroblasts and p6 human foreskin fibroblasts. Cre-mediated excision of the reprogramming transgenes has only been validated in the mouse system. Other cell types have not been tested and thus similar results can not be guaranteed. 使用声明 - Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
- This product contains genetically modified organisms (GMO). Within the EU GMOs are regulated by Directives 2001/18/EC and 2009/41/EC of the European Parliament and of the Council and their national implementation in the member States respectively. This legislation obliges Merck-Millipore to request certain information about you and the establishment where the GMOs are being handled.
储存和货运信息 存储条件 Lentivirus is stable for at least 6 months when stored at -80°C. After first thaw, place immediately on ice and store in working aliquots to avoid further freeze thaws. Avoid freeze thaws as this will result in a decrease in the virus titer. Polybrene transfection reagent is stable for at least 1 year when stored at -20°C. 包装信息 数量 1 kit
上一件merck millipore产品:merck millipore,默克密理博,5161,Penicillin G, Potassium Salt - CAS 113-98-4 - Calbiochem
下一件merck millipore产品:merck millipore,默克密理博,MABS12,Anti-GRK6 Antibody, clone 4B11.2
merck millipore,默克密理博,553901,Renin, Human Kidney
merck millipore,默克密理博,MAB3211,Anti-Lamin A/C Antibody, clone JoL2
merck millipore,默克密理博,SF-1417,SOX10; Mouse, Cyanine 3 RNA Detection Probe,SmartFlare
merck millipore,默克密理博,06-1076,Anti-IL-22 Antibody
merck millipore,默克密理博,5161,Penicillin G, Potassium Salt - CAS 113-98-4 - Calbiochem
merck millipore,默克密理博,MABS12,Anti-GRK6 Antibody, clone 4B11.2
merck millipore,默克密理博,MAB4155A4,Anti-BCRP1 Antibody, clone 5D3, Alexa Fluor 488 conjugate
merck millipore,默克密理博,MAB16985B,Anti-MCAM Antibody, clone P1H12, biotin conjugated
merck millipore,默克密理博,MAB2244,Anti-Nitrated Tau (Tyr29) Antibody, clone Tau-nY29
merck millipore,默克密理博,AB5401-25UL,Anti-Growth Associated Protein 43 Antibody, phosphoSer 41


