• merck millipore,默克密理博,FCXR600424,FlowCellect Chemokine Receptor CXCR6 Surface Expression Identification and Quantification Kit
  • merck millipore,默克密理博,FCXR600424,FlowCellect Chemokine Receptor CXCR6 Surface Expression Identification and Quantification Kit

    产品名称:FlowCellect Chemokine Receptor CXCR6 Surface Expression Identification and Quantification Kit
    产品型号:FCXR600424
    This FlowCellect GPCR Surface Identification Kit for Flow Cytometry is designed to provide an easier & more efficient way of characterizing GPCR expression on a given cell type of interest.

    merck millipore,默克密理博,FCXR600424,FlowCellect Chemokine Receptor CXCR6 Surface Expression Identification and Quantification Kit

  • 产品介绍
  • merck millipore,默克密理博,FCXR600424,FlowCellect Chemokine Receptor CXCR6 Surface Expression Identification and Quantification Kit

    描述
    产品目录编号 FCXR600424
    商名
    • FlowCellect
    描述 FlowCellect Chemokine Receptor CXCR6 Surface Expression Identification and Quantification Kit
    概述 Millipore’s FlowCellect™ GPCR Surface Identification kit is designed to provide an easier and more efficient way of characterizing GPCR expression on a given cell type of interest. This kit includes optimized buffers and a high affinity, specific antibody capable for detecting the GPCR target in question. Also included in the kit is a secondary antibody conjugate to R-Phycoerythrin, which is a bright fluorochrome ideal for measuring endogenous levels of GPCR expression on native cells. By following the steps outlined in the assay procedure, researchers can easily identify which native cell lines would be suitable for performing secondary assays in support of their structure-activity drug discovery efforts.

    Additional test applications include the identification of high, medium, and low expressing cell cultures during the clonal selection process. When a researcher decides to build a stable cell line in-house, it is essential that the clone of choice will provide the GPCR surface expression needed to perform drug screening. Choosing the wrong clone can adversely affect a primary screen if the chosen clone cannot detect lower affinity compounds. This can lead to a lower hit rate, which can result in screening limitations when identifying potential blockbuster compounds.

    Another added feature is the ability to quantitatively measure GPCR cell surface expression using flow cytometry as the method for detection. Provided in the kit are two vials of Millipore’s ChemiScreen™ GPCR cell lines, serving as assay controls. Using patented technology, Millipore’s ChemiScreen™ GPCR cell lines retain high surface expression as illustrated by the relatively high maximal number of binding sites (Bmax value) when compared to a native system.

    By using Millipore’s FlowCellect™ Chemokine Receptor Surface Expression Identification kit, the researcher has the ability to identify a native GPCR expressing cell for biological assay development; the researcher can also easily select clonal stable cell lines for these GPCRs; finally, the researcher can monitor the changes of these receptor expression levels during a disease state.
    Alternate Names
    • Flow Cellect
    背景信息 The FlowCellect™ GPCR identification kits are designed for flow cytometry applications, which can be used for the identification and quantification of the surface expression level of GPCRs on any cells. The kit uses a GPCR antibody validated for flow cytometry to detect receptor expression, and also includes both positive and negative control cells with well characterized receptor expression levels for the purpose of quantification.

    Chemokine receptors are very attractive targets because they are highly expressed on immune cells and regulate leukocyte activation and trafficking. Many of these targets have been indicated to play a key role in certain diseases states such as HIV infection, Rheumatoid Arthritis, and Diabetes. The expression levels of these receptors often reflect the different states of infectious diseases and inflammation.

    Chemokine receptors are seven transmembrane G-Protein coupled receptors (GPCRs). The chemokine receptor family comprises of eighteen GPCR targets, in which ten are CC chemokine receptors, seven are CXC chemokine receptors, and one is a CX3C chemokine receptor. Currently, Millipore has launched 12 GPCR surface identification kits with an initial focus on the chemokine receptor family.

    The GPCR CXCR6 (previously known as BONZO, STRL33 and TYMSTR) binds selectively to the free chemokine domain of CXCL16, which is derived from a membrane-bound precursor containing a CXC-containing chemokine domain, a glycosylated mucin-like domain, and a transmembrane domain [1]. CXCR6 is selectively expressed on Th1, Th2 and Tr1 T cell subsets, whereas CXCL16 is expressed on monocytes/macrophages and dendritic cells [2]. CXCR6 promotes migration of activated lymphocytes to sites of inflammation in tissues such as liver and synovium [3,4].

    The control cells provided in the kit are based on the commercially available ChemiScreen™ GPCR stable cell lines from Millipore. Both the positive and negative control cell lines have been fully characterized using Pharmacology techniques such as radioligand binding assay to determine the receptor number for each cell type [5]. Using this information, now the researcher can determine the number of receptors per cell on any given cell type.
    产品信息
    部件
    • 8. Negative Control Cell Culture for CXCR6 : - (Part No. CS202121) One vial supplied with 4x106 cells
    • 1. 500X Mouse anti-human CXCR6 Monoclonal Antibody
    • Clone ID 56811: - (Part No. CS202142) One 20uL vial
    • 2. 500X Secondary Antibody conjugated to R-Phycoerythrin: - (Part No. CS202129) One 20uL vial
    • 3. Antibody Diluent: - (Part No. CS202130) One 1mL vial
    • 4. Fixation Buffer: - (Part No. CS202122) One 13mL bottle
    • 5. 10X Wash Buffer: - (Part No. CS202123) One 13mL bottle
    • 6. 5X Assay Buffer: - (Part No. CS202124) One 55mL bottle
    • 7. Positive Control Cell Culture for CXCR6 : - (Part No. CS202392) One vial supplied with 4x106 cells
    检测方法 125IFluorescent
    应用
    应用 This FlowCellect GPCR Surface Identification Kit for Flow Cytometry is designed to provide an easier & more efficient way of characterizing GPCR expression on a given cell type of interest.
    主要应用
    • Flow Cytometry
    生物信息
    宿主 Mouse
    品种反应性 Human
    抗体类型 Monoclonal Antibody
    产品使用声明
    质量保证 Lot to lot in-process testing on all kit components
    使用声明
    • Alexa Fluor® is a registered trademark of Molecular Probes, Inc.
    • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
    储存和货运信息
    存储条件 4-8°C for antibodies and buffers; -80°C for positive and negative control cells; 6 Months
    包装信息
    数量 100 Tests / Kit

    merck millipore,默克密理博,FCXR600424,FlowCellect Chemokine Receptor CXCR6 Surface Expression Identification and Quantification Kit

上一件merck millipore产品:merck millipore,默克密理博,506282,PAD Inhibitor, Cl-amidine - Calbiochem
下一件merck millipore产品:merck millipore,默克密理博,05-1000X,Anti-Phosphoserine Antibody, clone 4A4



whatman,沃特曼,nalgene,耐洁,merck millipore,默克密理愽,sartorius,赛多利斯,pall,颇尔
thermo fisher,赛默飞世尔,GE,MN,macherey-nagel,advantec,wheaton,brand,普兰德,welch,airtech


上海羽令过滤器材有限公司版权所有 Copyright ©  www.yl-guolv.com  Powered by 羽令集团—信息技术部