• pall,颇尔,AcroPrep 24 过滤系统,289000159, 186000158, 600000158, 186000154, 186000154P
  • pall,颇尔,AcroPrep 24 过滤系统,289000159, 186000158, 600000158, 186000154, 186000154P

    产品名称:AcroPrep 24 过滤系统
    产品型号:289000159, 186000158, 600000158, 186000154, 186000154P


    pall,颇尔,AcroPrep 24 过滤系统,289000159, 186000158, 600000158, 186000154, 186000154P

  • 产品介绍
  • pall,颇尔,AcroPrep 24 过滤系统

    AcroPrep 24 过滤系统

    Eliminates the Time-consuming, One-at-a-time Syringe Filter Process by Simultaneously Filtering Up to 24 Samples in Seconds

    • 与传统针头过滤器技术相比,每个圆盘传送带可节省 20 分钟劳动时间。
    • No need to use cumbersome, individually wrapped, disposable syringes.Use disposable pipette tips which are less costly, easier to use, and require less bench space.
    • Designed for use with Waters Alliance* HPLC systems.
    • 颇尔's HPLC certification ensures that analytical results will not be compromised by extractable filter material.
    • No cross-contamination.Each 1.9 mL well is individually sealed, ensuring your sample will accurately dispense into the Waters Alliance sample carousel* with no crosscontamination or splashing.
    • Materials of construction are identical to 颇尔's Acrodisc® syringe filters; if you are currently using Acrodisc syringe filters, this will reduce the requirements for validation of the AcroPrep 24 filter plates.
    • Can be used with any conventional 12 x 32 mm vials; simply transfer your filtered samples from the Waters Alliance sample carousel to any HPLC sample carousel that houses 12 x 32 mm vials and save both time and labor.
    • Can be used to process fewer than 24 samples.Simply label used wells or isolate unused wells with parafilm for application at a later time.
    *The Water's Alliance 2690 Sample Carousel kit (PN WAT270328) can be ordered directly from your local Waters sales office or contact Waters Corporation at 800-252-4752 (in the U.S.) or 508-478-2000.
     
     
    • Ideal for use with HPLC sample preparation
     
     

    材料成分

    • Filter Media:GH Polypro (GHP, hydrophilic polypropylene), nylon, PTFE, and PVDF membranes
    • Housing:聚丙烯

     

    孔径

    • 0.2 and 0.45 μm

     

    Effective Filtration Area/Well

    • 0.94 cm2

     

    Filter Plate Diameter

    • 15.24 cm (6.0 in.) plate containing 24 wells

     

    Outlet Connections

    • Minispike outlet

     

    Maximum Well Volume

    • 1.9 毫升

     

    Recommended Sample Volume

    • 1.7 毫升

     

    Typical Hold-Up Volume/Well

    • < 50 μL

     

    操作温度范围

    • 18 - 27 °C (64 - 80 °F); ambient

     

    Maximum Vacuum

    • 56.0 cm Hg (22 in.Hg)

     

    化学兼容性

     
     

    The AcroPrep 24 Filtration System Saves Time and Materials

     

     
    Syringe Filter Technique AcroPrep 24 过滤系统
    24 disposable syringes 24 disposable pipette tips
    + 24 syringe filters +1 AcroPrep 24 filter plate
    25 minutes 5 minutes
     
     

    Instructions for Use

    The AcroPrep 24 Filtration System operates by vacuum.Conventional lab pumps such as 颇尔 Life Sciences’s 115 V (PN 13157) or 230 V (PN 13158)Vacuum/Pressure pumps are ideal for use. For maximum convenience, we recommend the use of snap-cap vials to eliminate the need to remove vials for screw capping after filtration.
      1. Attach vacuum hose to the barbed connection on the base.
      2. Place your Alliance sample carousel with empty 2 mL vials into the manifold.
        AcroPrep Filtration System Sample Carousel

         

      3. Place the filter plate onto the manifold.The filter plate has a numerically sequenced label that matches the carousel’s sample numbers.

         

         

      4. Pipette 1.7 mL (1,700 μL) of sample into each of the filter wells.
      5. Apply vacuum.

         

         

      6. Allow vacuum to run until all wells are evacuated.
      7. Shut off vacuum source.Dispose of filter plate.

         

         

      8. Cap sample vials and place the sample carousel into the Waters Alliance HPLC system or simply transfer the vials to any HPLC sample carousel that houses 12 x 32 mm vials.

         

     

    The cleanliness of the AcroPrep filter plate results in very low levels of extractables, therefore eliminating the need to pre-rinse the filter.MP>

     

    Vacuum General Information

    • Do not exceed a vacuum level of 56.0 cm (22 in.)Hg.
    • Allow vacuum to run until all filter wells are evacuated.Continue running vacuum for 10 to 20 seconds to eliminate potential dripping of samples from tips when plate is removed.
    Part Number 描述 Pkg Price Qty
    AcroPrep 24 Filtration System Manifold
    289000159 Filtration manifold 1/pkg Call
    AcroPrep 24 滤板
    186000158 0.2 µm, GHP membrane 10/pkg Call
    600000158 0.45 µm, GHP membrane 2/pkg Call
    186000154 0.45 µm, GHP membrane 10/pkg Call
    186000154P 0.45 µm, GxF/GHP filter plates 10/pkg Call
    配件及替换部件
    13157 真空/压力泵,115 V 1/pkg Call
    13158 Vacuum/Pressure pump, 230 V CE 1/pkg Call
    700000231 Glass housing for filtration manifold 1/pkg Call
    700000232 O-ring kit 3/pkg Call
    700000233 Rubber feet 3/pkg Call
    700000234 Manifold alignment post 3/pkg Call
     

     


    pall,颇尔,AcroPrep 24 过滤系统

上一件pall产品:pall,颇尔,Supor 膜的 AcroPak 500、1000 和 1500 囊式过滤器,12997, 12995, 12991, 12993, 12999, 12996, 12992, 12994, 12686, 12675
下一件pall产品:pall,颇尔,AcroPrep 384 孔板,100 µL,5076, 5077, 5078, 5079, 5080, 5081, 5086, 5070, 5071, 5072, 5073, 5073W, 5084, 5085



whatman,沃特曼,nalgene,耐洁,merck millipore,默克密理愽,sartorius,赛多利斯,pall,颇尔
thermo fisher,赛默飞世尔,GE,MN,macherey-nagel,advantec,wheaton,brand,普兰德,welch,airtech


上海羽令过滤器材有限公司版权所有 Copyright ©  www.yl-guolv.com  Powered by 羽令集团—信息技术部