• merck millipore,默克密理博,FCCH100109,FlowCellect MitoStress Kit
  • merck millipore,默克密理博,FCCH100109,FlowCellect MitoStress Kit

    产品名称:FlowCellect MitoStress Kit
    产品型号:FCCH100109
    This FlowCellect MitoStress Kit for Flow Cytometry includes MitoSOX Red, a live-cell permeant fluorogenic dye & Annexin V conjugated to CF647 which binds to phosphatidylserine (PS) on the surface of a More>>

    merck millipore,默克密理博,FCCH100109,FlowCellect MitoStress Kit

  • 产品介绍
  • merck millipore,默克密理博,FCCH100109,FlowCellect MitoStress Kit

    描述
    产品目录编号 FCCH100109
    商名
    • FlowCellect
    描述 FlowCellect MitoStress Kit
    概述 Millipore’s FlowCellect™ MitoStress Kit includes MitoSOX Red, a live-cell permeant fluorogenic dye which targets the mitochondria and reacts with superoxide radicals and fluoresces yellow/red, and Annexin V conjugated to CF647 which binds to phosphatidylserine (PS) on the surface of apoptotic cells. The simultaneous use of these reagents allows researchers to obtain information on oxidative stress and apoptosis in one simple assay.

    MitoSOX Red is excitable by a 488nm laser and fluoresces maximally at 580 nm (Yellow fluorescence on the guava easyCyte 8HT). Annexin V is calcium-dependent phospholipid binding protein with high affinity for PS, a membrane component normally localized to the internal face of the cell membrane. It is conjugated to CF647 which is excited by a red laser and emits at 665 nm (Red2 fluorescence on the guava easyCyte 8HT). Control cells depict no Red2 fluorescence while apoptotic cells exhibit positive Red2 fluorescence. The kit can thus distinguish multiple populations: 1) Live cells with little or no superoxide 2) Stressed cells with oxidized MitoSOX Red (indicator of accumulated superoxide) but no Annexin V staining 3) Stressed and Early Apoptotic cells with oxidized MitoSOX Red and Annexin V binding and 4) Apoptotic Cells with Annexin V binding only., The MitoStress kit rapidly provides information on correlation of mitochondrial superoxide stress with apoptosis using minimal cellular sample. The entire assay can be performed in less than 30 minutes, once cellular samples are ready.
    Alternate Names
    • FlowCellect
    产品信息
    部件
    • User Manual
    • MitoSOX Red
    • Annexin V CF647
    • 10X Assay Buffer
    检测方法 Fluorescent
    应用
    应用 This FlowCellect MitoStress Kit for Flow Cytometry includes MitoSOX Red, a live-cell permeant fluorogenic dye & Annexin V conjugated to CF647 which binds to phosphatidylserine (PS) on the surface of apoptotic cells.
    主要应用
    • Flow Cytometry
    生物信息
    品种反应性 Human
    产品使用声明
    使用声明
    • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
    包装信息
    数量 100 Tests

    merck millipore,默克密理博,FCCH100109,FlowCellect MitoStress Kit

上一件merck millipore产品:merck millipore,默克密理博,362338,Glyco-SNAP-1 - Calbiochem
下一件merck millipore产品:merck millipore,默克密理博,MAB3086,Anti-Ryanodine Receptor Antibody, clone RYR.1



whatman,沃特曼,nalgene,耐洁,merck millipore,默克密理愽,sartorius,赛多利斯,pall,颇尔
thermo fisher,赛默飞世尔,GE,MN,macherey-nagel,advantec,wheaton,brand,普兰德,welch,airtech


上海羽令过滤器材有限公司版权所有 Copyright ©  www.yl-guolv.com  Powered by 羽令集团—信息技术部