• merck millipore,默克密理博,QIA63,MMP-2 ELISA Kit
  • merck millipore,默克密理博,QIA63,MMP-2 ELISA Kit

    产品名称:MMP-2 ELISA Kit
    产品型号:QIA63


    merck millipore,默克密理博,QIA63,MMP-2 ELISA Kit

  • 产品介绍
  • merck millipore,默克密理博,QIA63,MMP-2 ELISA Kit

    重要规格表

    检测方法
    Colorimetric
    描述
    概述 A non-isotopic colorimetric assay for the in vitro assay of human MMP-2 protein in tissue culture media, serum, or plasma.
    产品目录编号 QIA63
    品牌系列 Calbiochem®
    同义词 Gelatinase A ELISA Kit, 72 kDa Gelatinase ELISA Kit, Matrix Metalloproteinase 2 ELISA Kit
    应用数据
    The assay has a 30% percent clinical sensitivity (ability to recognize affected individuals) at a 95% clinical specificity (ability to recognize unaffected individuals).

    Astrocytoma and HS578T cells were plated out at various cell densities into 96 plate wells. Cells were incubated at 37°C for 24 h. Supernatant was measured in the MMP-2 ELISA. MMP-2 levels were detectable at cell concentrations of 4 X 103 Astrocytoma cells/well and 0.6 X 104 HS578T cells/well and above.

    The lower limit of detection (LLD), commonly used to define sensitivity, was measured by assaying four replicates of zero eight times using two different lots of plates and two different lots of detector antibody. The grand mean signal and pooled standard deviation of zero was calculated. The grand mean of each standard (run in replicates of four in the eight assays) was used for the standard curve, and the response, mean signal of zero plus two standard deviations, read in dose from the standard curve is the LLD; that is, the smallest dose that is not zero with 95% confidence.

    The pooled coefficients of variation (according to the formula of Henry et. al., 1974) and between assay coefficients of variation are plotted against MMP-2 concentrations. The pooled data were collected from samples run eight times using two different lots of plates and two different lots of detector antibody in replicates of three on two separate occasions.

    The study tested dilution-recovery of 28 positive samples. Dilutions were run in the MMP-2 ELISA and the "found" doses were plotted against the "expected" doses to determine linearity of dilution. The slope is very close to one and the intercept is not significantly different from zero. These studies are consistent with the absence of cross-reacting and matrix effects such as pH, salts, and endogenous binders that interfere with the reagents used in the assay. Note: Ca = Cancer; NHS = Normal Human Sera; TC= Tissue Culture.

    Levels of MMP-2 detected by the ELISA after immunoaffinity extraction of MMP-2 positive samples with a MMP-2 antibody that is not used in the ELISA and a control antibody.

    Levels of a highly purified 72 kDa MMP-2 that exists in a stable, but non-covalent 1:1complex with TIMP-2 detected after neutralization with a MMP-2 antibody that is not used in the ELISA.

    Levels of MMP-2 detected by the MMP-2 ELISA after 2-aminophenylmercuric acetate (APMA) treatment. APMA promotes the autocatalytic cleavage of the N-terminal prosequence of the latent 72-kDa enzyme to yield the active form of the enzyme. HT1080 and astrocytoma tissue culture supernatants, recombinant proMMP-2 and normal human serum samples were either untreated (-APMA) or incubated for four hours at 37°C with 2 mM APMA (+APMA) or a volume of DMSO to control for the DMSO base of APMA (Vehicle Ctrl).

    Levels of MMP-2 detected by the ELISA after immunoaffinity extraction of MMP-2 positive samples with a MMP-2 antibody that is not used in the ELISA and a control antibody.
    产品信息
    检测方法 Colorimetric
    声明 Not available for sale in Japan.
    形式 34 or 41 Tests
    格式 96-well plate
    试剂盒包含 Anti-MMP-2 Coated 96-Well Plate, MMP-2 Standard, Detector Antibody, 400X Conjugate, Conjugate Diluent, Substrate, Sample Diluent, Plate Wash Concentrate, Stop Solution, Plate Sealers, and a user protocol.
    生物信息
    化验范围 1.56 - 50 ng/ml
    化验时间 5.5 h
    样品类型 Tissue culture medium, serum, or plasma
    品种 human
    理化信息
    灵敏度 0.1 ng/ml
    安全信息
    R相 R: 23/24/25-35-36/37/38-40-43

    Toxic by inhalation, in contact with skin and if swallowed.
    Causes severe burns.
    Irritating to eyes, respiratory system and skin.
    Limited evidence of a carcinogenic effect.
    May cause sensitization by skin contact.
    S相 S: 23-26-36/37/39-45

    Do not breathe fumes.
    In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
    Wear suitable protective clothing, gloves and eye/face protection.
    In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).
    产品使用声明
    预定用途 The Calbiochem® MMP-2 ELISA Kit is a non-isotopic immunoassay for the in vitro quantitation of human MMP-2 protein in tissue culture medium, serum, and plasma.
    储存和货运信息
    货运代码 Dry Ice Only
    毒性 Multiple Toxicity Values, refer to MSDS
    有害材料注意事项: Due to the nature of the Hazardous Materials in this shipment, additional shipping chargesmay be applied to your order. Certain sizes may be exempt from the additional hazardous materials shipping charges. Please contact your local sales office for more information regarding these charges.
    储存 -20°C
    存储条件 Upon arrival, store the entire contents at -20°C. Avoid multiple freeze/thaw cycles. Do not expose reagents to excessive light.
    避免冻结 / 解冻 Avoid freeze/thaw
    无需冷冻 No
    补充信息
    试剂盒包含 Anti-MMP-2 Coated 96-Well Plate, MMP-2 Standard, Detector Antibody, 400X Conjugate, Conjugate Diluent, Substrate, Sample Diluent, Plate Wash Concentrate, Stop Solution, Plate Sealers, and a user protocol.

    merck millipore,默克密理博,QIA63,MMP-2 ELISA Kit

上一件merck millipore产品:merck millipore,默克密理博,361568,GSK-3β Inhibitor XXV - Calbiochem
下一件merck millipore产品:merck millipore,默克密理博,MAB8257-K,Anti-Influenza A, Nucleoprotein, Clone A1



whatman,沃特曼,nalgene,耐洁,merck millipore,默克密理愽,sartorius,赛多利斯,pall,颇尔
thermo fisher,赛默飞世尔,GE,MN,macherey-nagel,advantec,wheaton,brand,普兰德,welch,airtech


上海羽令过滤器材有限公司版权所有 Copyright ©  www.yl-guolv.com  Powered by 羽令集团—信息技术部